Residential & Light-Commercial Steam Generators
PERFECT FOR STEAM ON DEMAND
With fast steam production, Warm Start™, and a variety of intuitive controls, the AX and AK steam generators are the right choice for your home or light-commercial steam room.
AX SERIES GENERATOR
We have designed our AX series generators for long lasting performance and reliability. Consistent and even flow of steam are unique Amerec features that set our generators apart. AmerecControl app is a Free download for Android and IOS. It provides on/off control via Wi-Fi with your Elite control on AX steam units. A PC version is also available.
|
AX SERIES WITH ELITE AND PURE 2.0 TOUCH CONTROLS AND AUTO DRAIN
|
Model | Min Cu Ft | Max Cu Ft | Voltage | Power (Watts) | Amps (1 Ph) | Breaker | Amps (3 Ph) | Breaker |
AX4.5 | 60 | 90 | 240 | 4500 | 19 | 30 | 11 | 15 |
AX4.5 | 60 | 90 | 208 | 4500 | 22 | 30 | 12 | 20 |
AX6 | 80 | 150 | 240 | 6000 | 25 | 40 | 14 | 20 |
AX6 | 80 | 150 | 208 | 6000 | 29 | 40 | 17 | 30 |
AX7.5 | 100 | 200 | 240 | 7500 | 31 | 40 | 18 | 30 |
AX7.5 | 100 | 200 | 208 | 7510 | 36 | 50 | 21 | 30 |
AX9 | 150 | 300 | 240 | 9000 | 38 | 50 | 22 | 30 |
AX9 | 150 | 300 | 208 | 9000 | 43 | 60 | 25 | 40 |
AX11 | 200 | 400 | 240 | 11000 | 46 | 60 | 26 | 40 |
AX11 | 200 | 400 | 208 | 11250 | 18 & 36 | 30 & 50 | 31 | 40 |
AX14 | 350 | 550 | 240 | 14000 | 21 & 38 | 30 & 50 | 34 | 50 |
AX14 | 350 | 550 | 208 | 13850 | 24 & 42 | 30 & 50 | 38 | 50 |
To calculate the generator size required, multiply the length x width x height of the steam room.
For rooms made of natural stone, multiply the cubic volume by 1.75 (stone requires more power to heat).
(Maximum recommended ceiling height is 8 feet.)
For rooms exceeding 550 cubic feet, generators may be ganged together to achieve required capacity.
Each generator will require its own power source as described in the chart above.
Example: Room size 750 cu ft, power available 240V 1 phase:
Use two AX11 generators
Requires one 60A circuit for each AX11 steamer (total of two circuits)
Example: Room size 925 cu ft power available 240V 1 phase:
Use one AX11 (requires one 60A circuit) plus one AX14
(requires 2 circuits, one 30A + one 50A)
One control required, regardless of quantity of generators. Additional controls may be connected.
AX steamers are compatible with Amerec's Elite and Pure 2.0 control.
Dual control options: Elite+Wi-Fi app, Elite+Elite, or Elite+Pure 2.0
AK SERIES GENERATOR
The soothing and purifying effects of steam bathing are a direct result of the bath’s ability to minimize temperature variations and maintain an even flow of steam. Amerec AK generators were purpose-designed for home use, transforming your shower or bathing room into a daily
invitation to comfort. An AK generator uses full power to quickly heat up the steam room to its preset temperature, then cuts power by 1/3 or 2/3 of its heating elements. The result is a more consistent flow of soft steam and more stable temperature – the perfect conditions for relaxing and recharging whenever the mood strikes you.
|
AK SERIES WITH K60 AND KT60 DIGITAL CONTROLS OR R30K ON/OFF CONTROL AND AUTO DRAINPerformance Features of Amerec AK Generators:
Owner's Manual:AK Installation & Owner's Manual
|
Model | Min Cu Ft | Max Cu Ft | Voltage | Power (Watts) | Amps (1 Ph) | Breaker | Amps (3 Ph) | Breaker |
AK4.5 | 60 | 90 | 240 | 4500 | 19 | 30 | 11 | 15 |
AK4.5 | 60 | 90 | 208 | 4500 | 22 | 30 | 12 | 20 |
AK6 | 80 | 150 | 240 | 6000 | 25 | 40 | 14 | 20 |
AK6 | 80 | 150 | 208 | 6000 | 29 | 40 | 17 | 30 |
AK7.5 | 100 | 200 | 240 | 7500 | 31 | 40 | 18 | 30 |
AK7.5 | 100 | 200 | 208 | 7510 | 36 | 50 | 21 | 30 |
AK9 | 150 | 300 | 240 | 9000 | 38 | 50 | 22 | 30 |
AK9 | 150 | 300 | 208 | 9000 | 43 | 60 | 25 | 40 |
AK11 | 200 | 400 | 240 | 11000 | 46 | 60 | 26 | 40 |
AK11 | 200 | 400 | 208 | 11250 | 18 & 36 | 30 & 50 | 31 | 40 |
AK14 | 350 | 550 | 240 | 14000 | 21 & 38 | 30 & 50 | 34 | 50 |
AK14 | 350 | 550 | 208 | 13850 | 24 & 42 | 30 & 50 | 38 | 50 |
To calculate the generator size required, multiply the length x width x height of the steam room.
For rooms made of natural stone, multiply the cubic volume by 1.75 (stone requires more power to heat).
(Maximum recommended ceiling height is 8 feet.)
For rooms exceeding 550 cubic feet, generators may be ganged together to achieve required capacity.
Each generator will require its own power source as described in the chart above.
Example: Room size 750 cu ft, power available 240V 1 phase:
Use two AK11 generators
Requires one 60A circuit for each AK11 steamer (total of two circuits)
Example: Room size 925 cu ft power available 240V 1 phase:
Use one AK11 (requires one 60A circuit) plus one AK14
(requires 2 circuits, one 30A + one 50A)
One control required, regardless of quantity of generators. Additional controls may be connected.
AK steamers are compatible with Amerec's KT60 Control.